项目背景
There are three existing 1x630MW supercritical boiler. Before denitration, the NOx concentration is about 400mg/ Nm3, and the design value of low nitrogen +SNCR emission concentration is ≤150mg/ Nm3 (6% oxygen content in dry basis).At present, it is planned to carry out ultra-low emission on the boilers, aiming to reach the NOX emission concentration in the the level of 30~50mg/Nm3 (6% oxygen content in dry basis).
SCR Reconstruction of No.4 Boiler Flue Gas Denitrification in Datang Xiangtan Power Generation Co., Ltd. (EPC)

出水标准

Adopt the latest national standard or general international standard

技术特点

SCR denitration efficiency is 80~ 90%;

When SCR is put into normal operation, the ammonia escape concentration of denitration device is 2.0~2.5 ppm;

When SCR is put into normal operation, the conversion rate of SO2/SO3 is less than 0.75%;

The availability rate of the whole denitration system is more than 98% in one year after the formal handover;

Under the condition of BMCR and the NOx concentration in flue gas: 400mg/Nm3 (standard state, dry basis, 6% oxygen), Party B shall ensure that the urea consumption of each furnace is ≤ 115kg/h (total consumption of SNCR and SCR system).


解决方案

Plus SCR on the basis of Low NOx + SNCR

取得效果

Make the NOx emission concentration in the reformed flue gas be 30~50mg/Nm3 (6% oxygen in dry basis).